Lawrence G. Rubin
Automated 0.75-mm Spectrometer
Jobin Yvon has introduced the 750S scanning spectrometer and the
750I imaging spectrograph. Both instruments feature a 0.75-mm focal
length, a dispersion of 1.1 nm/mm, an accuracy of ±0.05 nm, and a repeatability of ±0.03 nm. Both are equipped with motorized slits
adjustable from 0 to 0.2 mm in 2 mm steps,
an auto-calibrating precision wavelength drive system, and an
auto-calibrating grating system. The kinematically mounted 110 ´ 110 mm gratings are designed for easy
interchange. The user can select the optimum resolution or spectral
coverage by choosing from among more than 50 individually mounted
gratings. The 750S is compatible with the company's photomultiplier
tubes and IR detectors; the 750I can be integrated with Jobin Yvon's
CCDs and indium gallium arsenide arrays. Jobin Yvon Inc, Optical
Spectroscopy Division, 3880 Park Avenue, Edison, New Jersey 08820,
http://www.jyhoriba.com/
Circle number 181 on Reader Service Card
Mini Spectrometers
BaySpec has released the IntelliSpectro mini parallel
spectrometer, an integrated optical module that uses the company's
volume phase grating technology. The model 101 module offers a
200-2000-nm wavelength range with a wavelength accuracy of ±0.40 nm. It incorporates a thermoelectrically
cooled indium gallium arsenide linear photodiode array with 256 or
512 elements and high-speed electronics. With a fiberoptic input and
parallel data acquisition and processing computer interfaces, the
101 can be applied to analytical instrumentation, biochemical
spectrum analysis, Raman and fluorescence measurements, and many
other tasks. Also available in the IntelliSpectro series are the
models 102 and 103, designed as spectrograph/spectrometer engines
for portable wavelength-division-multiplexing optical spectrum
analyzers. BaySpec Inc, 101 Hammond Avenue, Fremont, California
94539, http://www.bayspec.com/
Circle number 182 on Reader Service Card
Multifiber Imaging Spectrometer
McPherson has developed the model 2035, a UV-visible-NIR
spectrometer system optimized for monitoring fiber-coupled
reflecting telescopes in spectroscopy and imaging experiments. The
350-mm focal length spectrometer delivers 0.1-mm scale images near
axis with better than 0.1-nm spectral resolution over the 200-800-nm
wavelength range. Data capture and spectral diagnostics of
high-energy transient phenomena can be performed on multiple targets
on the nanosecond time scale. The receiving telescopes--available in
5.5- and 2-inch clear aperture--are equipped with parabolic optics
for optimal light gathering and signal delivery to fibers; doped and
UV-capable fibers are available. The spectrometer includes an
accessory to aperture match fast fibers to spectrometer fibers.
McPherson Inc, 7A Stuart Road, Chelmsford, Massachusetts
01824-4107, http://www.mcphersoninc.com/
Circle number 183 on Reader Service Card
Thermoelectrically-Cooled Detector
Roper Scientific has announced a thermoelectrically cooled
version of the Princeton Instruments OMA V detection system for NIR
spectroscopy applications. The new design enables efficient cooling
of a 512 ´ 1 indium gallium arsenide
photodiode array detector between 20 and -50°C. This system's
smaller, lighter camera head provides a convenient alternative to
its liquid-nitrogen-cooled counterpart. The OMA V:InGaAs detector
offers high sensitivity from 0.8-1.7 mm,
1-MHz digitization, 1800 spectra/s, and low read noise for both low-
and high-gain modes of operation, and is regulated by an
electromagnetically shielded detector controller. The system is well
suited for numerous spectroscopy methods, including Raman,
absorbance, and photoluminescence. Roper Scientific, 3440 East
Britannia Drive, Tucson, Arizona 85706-5006, http://www.roperscientific.com/
Circle number 184 on Reader Service Card
Fiberoptic Spectrometers
Two new options are available from StellarNet to enhance the
performance of the company's EPP2000 miniature fiberoptic
spectrometers. The LT14 Little Turbo digitizer is a 14-bit, 2.5
megasamples per second, A/D converter, that controls the optical
detector integration frame from less than 1 ms to 65 s for 2048
pixels. It improves the spectral speeds and dynamic range of the
EPP2000 by four times. Another option is the USB2EPP interface that
enables the spectrometer to provide much higher spectral data
transfers because the USB2 interface transports spectral data 40
times faster than older USB1 peripherals. The EPP2000-NIR
spectrometer incorporates a 512-element thermoelectrically cooled
indium gallium arsenide array detector in numerous models with
various operational ranges for UV, visible, and NIR (up to 1700 nm)
wavelengths. StellarNet Inc, 13801 McCormick Drive, Tampa,
Florida 33626, http://www.stellarnet-inc.com/
Circle number 185 on Reader Service Card
Portable Spectroradiometer
International Light's RPS 380 is a handheld instrument
for performing NIST-traceable spectroradiometric measurements in the
visible spectrum between 380 and 780 nm. The design provides for a
reduction in stray light to 10-4; that reduction is
essential for measurements of the weaker short wavelengths in most
broadband continua. The RPS 380 uses a multichannel detector for
rapid data acquisition (typically only several seconds) and assures
that there is no variance in the intensities due to source
fluctuations. The NIST-traceable measurements include those for
luminance, illuminance, radiance, irradiance, color temperature,
dominant wavelength purity, and chromaticity. The spectroradiometer
includes a USB interface and a laser targeting device for viewing
the exact coverage of the instrument. International Light Inc, 17
Graf Road, Newburyport, Massachusetts 01950, http://www.intl-light.com/
Circle number 186 on Reader Service Card
Time-of-Flight Detector
Burle Electro-Optics has introduced a time-of-flight (TOF)
detector with a 25-mm collection diameter for a variety of TOF mass
spectrometers. The detector uses the company's 5mm small-pore microchannel-plate (MCP) technology
and a new low profile matched impedance conical sensor to improve
mass resolution and sensitivity. The high channel density provides
dynamic range improvements said to be 10 times greater, and
subnanosecond pulse widths 10 times faster than conventional MCPs.
The detector's flat input surface provides uniform ion conversion
and the higher aspect ration of the MCP produces gains in excess of
107. Burle's Quick-Fit detector replacement cartridge
includes a Chevron set of two MCPs and a high-transmission grid
mounted in a rugged module. Burle Electro-Optics Inc, P.O. Box
1159, Sturbridge, Massachusettts 01566-1159, http://www.burle.com/
Circle number 187 on Reader Service Card
Low-Noise Silicon Photodiodes
Hamamatsu Corp has released the S8745 and S8746 Si photodiodes.
The large-area photodiodes are integrated with low-power dissipation
FET operational amplifiers and are well suited for UV to NIR
precision photometry designs such as spectrophotometry. The S8745 is
designed with a TO-5 package and has an active area of 2.4 ´ 2.4 mm; the S8746 uses a TO-8 housing and an
active area of 5.8 ´ 5.8 mm. The
photodiodes cover the 190-1100 nm wavelength range and have a
feedback resistance of 1 GW and a feedback
capacitance of 5 pF. That combination provides a sensitivity of 0.12
to 0.54 V/nW over the spectral range with peak sensitivity at 960
nm. At 10 Hz, the S8745 has an output noise voltage of 6 mV per root
Hz and an NEP of 11 fW per root Hz; for the S8746, the numbers are 7
mV per root Hz and 15 fW per root Hz, respectively. Hamamatsu
Corp, 360 Foothill Road, P.O. Box 6910, Bridgewater, New Jersey
08807, http://www.hamamatsu.com/
Circle number 188 on Reader Service Card
Raman Microscope
Renishaw's inVia Raman microscopes are high-sensitivity
systems that enable high-resolution confocal measurements. They
incorporate the company's RenCam CCD detector that offers ultralow
signal detection, making it well suited for Raman spectroscopy
applications, including the analysis of polymer coatings,
semiconductors, pharmaceuticals, diamond films, composites, and
ceramics. The inVia Reflex model microscope configuration provides
full automation, including automatic instrument reconfiguration and
validation when excitation wavelengths are switched, conversion to
confocal operation, and switching between white light sample viewing
and Raman acquisition modes. All other inVia configurations can be
upgraded stepwise through to the Reflex model at any time.
Renishaw plc, New Mills, Wotton-under-Edge, Gloucestershire GL12
8JR, United Kingdom, http://www.renishaw.com/
Circle number 189 on Reader Service Card
Goniometric Measurement Assembly
The OL 700-30 goniometer from Optronic Laboratories is designed
to operate with the company's OL 770-LED high-speed multichannel LED
test and measurement system, whose application software provides
control of the goniometer. The combined system offers spatial
radiation distribution measurements such as view angle, and maximum
intensity, chromaticity, tristimulus, relative power, peak
wavelength, and color temperature, all as a function of angle. The
OL 700-30 has an automated horizontal range of -90° to +90°, a minimum resolution of 0.01°, and a
maximum horizontal rotation rate of 15°/s at 1° measurement
intervals. It features the company's Activex controls and Software
Developers' Kit, which enables custom applications, including the
ones independent of the OL 770-LED. Optronic Laboratories Inc,
4632 36th Street, Orlando, Florida 32811, http://olinet.com/
Circle number 190 on Reader Service Card
Standard Platinum Resistance Thermometer
The Model 5698 Working Standard SPRT from Hart Scientific
features a strainfree, 25-ohm, pure platinum sensor. It meets the
ITS-90 ratio requirements for SPRTs and covers temperatures from
-200°C to 661°C. Long-term drift, which the company defines as the
change in output resistance at the triple-point of water after 100
hours at 661°C is--after converting to temperature--less than 6 mK
and typically less than 3 mK. The 5698 is enclosed in a 485-mm
quartz sheath and requires 1 mA of excitation current. Calibration
options include both fixed-point and comparison calibrations. Also
available from the company are SPRT readout devices such as the
model 1590, which reads the 5698 within an uncertainty of 1 mk at
0°C. Hart Scientific Inc, 799 East Utah Valley Drive, American
Fork, Utah 84003-9775, http://www.hartscientific.com/
Circle number 191 on Reader Service Card
Dual Ratemeter/Photon Counter
Advanced Research Instruments has introduced the PRM-400, a
precision dual ratemeter/photon counter. Capable of operating at
speeds of more than 500 MHz with zero dead-time operation, the
PRM-400 features what is sometimes referred to as back-to-back
counting: One of the dual counters is counting while the other is
unloading its data. The switching from one to the other is automatic
and instantaneous so that no counts are lost. The two counters can
also be configured for a background subtraction. The instrument
includes gated inputs, a 1024-point first-in-first-out data storage,
and a time base that provides ranges from 10 ms to 10 s. Each channel has an analog output and
a user-specified value for a threshold control of the
preamplifier/discriminator. Advanced Research Instruments Corp,
5151 Ward Road, Wheat Ridge, Colorado 80033http://www.aricorp.com/
Circle number 192 on Reader Service Card
X-ray Tube System
Amptek has announced the LASER-X, a laser-activated x-ray tube
system for portable x-ray fluorescence (XRF). It is designed to
simplify the XRF process by providing a grounded anode, variable
voltage and current, and ease of operation. It features a
35-kV/100-mA power supply (adjustable over
the range 10-35 kV) with a solid silver target, a collimated,
beryllium oxide end window, and control electronics. The x-ray beam
spot size is 1 mm in diameter and is directed 45° from the axis of
the tube. The internal miniature x-ray tube may be separated from
its enclosure where space is limited. The LASER-X is designed to
replace radioisotopes in XRF-analysis applications. The
laser-activated cathode allows instantaneous on-off, thus prolonging
battery life (a regulated +12-V supply may be used instead).
Amptek Inc, 6 De Angelo Drive, Bedford, Massachusetts 01730, http://www.amptek.com/
Circle number 193 on Reader Service Card
Water Jet Nozzles
Dynaflow has released its DynaJets high-efficiency water jet
nozzles that produce an extremely erosive environment said to enable
significant increases in cleaning, cutting, and drilling rates as
compared to conventional jet nozzles. DynaJets use cavitation,
acoustic excitation, and turbulent jet interruption and structuring
through passive manipulation of the flow to create large
high-frequency stresses on the target surface. The result is
high-efficiency jets for both submerged and in-air applications such
as surface cleaning, stripping, and rock cutting. Dynaflow Inc,
10621-J Iron Bridge Road, Jessup, Maryland 20791, http://www.dynaflow-inc.com/
Circle number 194 on Reader Service Card
On the Web
Magnetic Shield Update is a quarterly newsletter that
contains engineering notes, case studies, and general articles about
this field. Published by Magnetic Shield, the newsletter also
appears on the company's Web site. Magnetic Shield Corp, 740
North Thomas Drive, Bensenville, Illinois 60106, http://www.magnetic-shield.com/
Circle number 195 on Reader Service Card
New Literature
A new power supply catalog and handbook is available from Kepco.
Included in its 164 pages are revised and updated applications
information, a glossary, and full specifications on current products
and several new products, such as a group of bipolar, four-quadrant,
1-kW power supplies. Kepco Inc, 131-38 Sanford Avenue, Flushing,
New York 11352, http://www.kepcopower.com/
Circle number 196 on Reader Service Card
Thermo Vacuum Generators has released a 365-page color catalog
with complete specifications for thousands of high-vacuum and
ultra-high-vacuum components. Also included are tables of vacuum
data and guidelines for vacuum design. Thermo Vacuum Generators,
355 River Oaks Parkway, San Jose, California 95134, http://www.thermovacgen.com/
Circle number 197 on Reader Service Card
© 2003 American Institute of Physics
|
|
|